Ultrasonic cardiac output monitoring in intubated patients with and without COVID-19 in the ICU: a prospective cohort study

Abstract

Objective: The present study was conducted to compare mechanically ventilated patients with and without COVID-19 in terms of hemodynamic instability using cardiovascular indicators. Methods: This prospective cohort study assigned intubated and mechanically ventilated patients to two groups, i.e. with COVID-19 and without COVID-19. The hemodynamic parameters measured and compared between the two groups on the first day of ICU admission and the following four consecutive days using an ultrasonic cardiac output monitor (USCOM) included cardiac output (CO), systemic vascular resistance (SVR), stroke volume (SV), flow time corrected (FTc), minute distance (MD) and potential kinetic energy (PKE). Results: Forty-three patients (males: 62.7%) were assigned to the COVID-19 group and 40 (males: 64.1%) to the one without COVID-19. Insignificant differences were observed between the two groups at baseline in terms of the mean homodynamic variables measured using the USCOM (P>0.05). The mean CO increased (P=0.020), the mean SVR insignificantly changed (P=0.267), the mean MD increased (P=0.005) and PKE decreased (P=0.066) in the COVID-19 group during the five days of evaluation. In the same period, the mean CO insignificantly changed (P=0.937), the mean SVR increased (P=0.028) and changes in MD (P=0.808) and PKE (P=0.539) were insignificant in the group without COVID-19. The two groups were not significantly different in terms of the other homodynamic parameters during the follow-up (P>0.05). Conclusion: The five-day changes in the USCOM-measured homodynamic parameters were lower in the group without COVID-19 compared to in that with COVID-19. In the group without COVID-19, no statistically-significant differences were observed between the mean follow-up values of the variables, excluding SVR, and their baseline values.

1. Vahidi E, Jalili M. Why COVID-19? Adv J Emerg Med. 2020;4(2s):e36.
2. Grasselli G, Zangrillo A, Zanella A, Antonelli M, Cabrini L, Castelli A, et al. Baseline characteristics and outcomes of 1591 patients infected with SARS-CoV-2 admitted to ICUs of the Lombardy Region, Italy. JAMA. 2020;323(16):1574-81.
3. Jalali A, Karimialavijeh E, Babaniamansour P, Aliniagerdroudbari E, Babaniamansour S. Predicting the 30-day adverse outcomes of non-critical new-onset COVID-19 patients in emergency departments based on their lung CT scan findings; a pilot study for derivation an emergency scoring tool. Front Emerg Med. 2021;5(4):e40.
4. Gupta A, Madhavan MV, Sehgal K, Nair N, Mahajan S, Sehrawat TS, et al. Extrapulmonary manifestations of COVID-19. Nat Med. 2020;26(7):1017-32.
5. Chen N, Zhou M, Dong X, Qu J, Gong F, Han Y, et al. Epidemiological and clinical characteristics of 99 cases of 2019 novel coronavirus pneumonia in Wuhan, China: a descriptive study. Lancet. 2020;395(10223):507-13.
6. Naderpour Z, Saeedi M. A primer on covid-19 for clinicians: clinical manifestation and natural course. Adv J Emerg Med. 2020;4(2s):e62.
7. National Health Commission. Diagnosis and treatment protocol for novel coronavirus pneumonia (trial version 7). Chin Med J (Engl). 2020;133(9):1087-95.
8. Baratloo A, Rahmati F, Rouhipour A, Motamedi M, Gheytanchi E, Amini F, et al. Correlation of blood gas parameters with central venous pressure in patients with septic shock; a pilot study. Bull Emerg Trauma. 2014;2(2):77-81.
9. Matthay MA, Aldrich JM, Gotts JE. Treatment for severe acute respiratory distress syndrome from COVID-19. Lancet Respir Med. 2020;8(5):433-4.
10. Sadeghi R, Toloui A, Pourhoseingholi A, Taherpour N, Sistanizad M, Omidi F, et al. The prognostic value of echocardiographic findings in prediction of in-hospital mortality of COVID-19 patients. Front Emerg Med. 2021;5(4):e38.
11. Rahim-Taleghani S, Fatemi A, Moghaddam MA, Shojaee M, Abushouk AI, Forouzanfar MM, et al. Correlation of central venous pressure with venous blood gas analysis parameters; a diagnostic study. Turk J Emerg Med. 2016;17(1):7-11.
12. Marik PE. Noninvasive cardiac output monitors: a state-of the-art review. J Cardiothorac Vasc Anesth. 2013;27(1):121-34.
13. Porter TR, Shillcutt SK, Adams MS, Desjardins G, Glas KE, Olson JJ, et al. Guidelines for the use of echocardiography as a monitor for therapeutic intervention in adults: a report from the American society of echocardiography. J Am Soc Echocardiogr. 2015;28(1):40-56.
14. D’Alto M, Dimopoulos K, Coghlan JG, Kovacs G, Rosenkranz S, Naeije R. Right heart catheterization for the diagnosis of pulmonary hypertension: controversies and practical issues. Heart Fail Clin. 2018;14(3):467-77.
15. Walker A, Olsson E, Wranne B, Ringqvist I, Ask P. Accuracy of spectral Doppler flow and tissue velocity measurements in ultrasound systems. Ultrasound Med Biol. 2004;30(1):127-32.
16. Nidorf SM, Picard MH, Triulzi MO, Thomas JD, Newell J, King ME, et al. New perspectives in the assessment of cardiac chamber dimensions during development and adulthood. J Am Coll Cardiol. 1992;19(5):983-8.
17. Shang Y, Pan C, Yang X, Zhong M, Shang X, Wu Z, et al. Management of critically ill patients with COVID-19 in ICU: statement from front-line intensive care experts in Wuhan, China. Ann Intensive Care. 2020;10(1):73.
18. Michard F, Malbrain ML, Martin GS, Fumeaux T, Lobo S, Gonzalez F, et al. Haemodynamic monitoring and management in COVID-19 intensive care patients: an international survey. Anaesth Crit Care Pain Med. 2020;39(5):563-9.
19. Szekely Y, Lichter Y, Taieb P, Banai A, Hochstadt A, Merdler I, et al. Spectrum of cardiac manifestations in COVID-19: a systematic echocardiographic study. Circulation. 2020;142(4):342-53.
20. Caravita S, Baratto C, Di Marco F, Calabrese A, Balestrieri G, Russo F, et al. Haemodynamic characteristics of COVID‐19 patients with acute respiratory distress syndrome requiring mechanical ventilation. An invasive assessment using right heart catheterization. Eur J Heart Fail. 2020;22(12):2228-37.
21. Tan H, Pinder M, Parsons R, Roberts B, Van Heerden P. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth. 2005;94(3):287-91.
22. Chand R, Mehta Y, Trehan N. Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery. J Cardiothorac Vasc Anesth. 2006;20(3):315-9.
23. Marcelino P, Germano N, Marum S, Fernandes AP, Ribeiro P, Lopes MG. Haemodynamic parameters obtained by transthoracic echocardiography and Swan-Ganz catheter: a comparative study in liver transplant patients. Acta Med Port. 2006;19(3):197-205.
24. Abdolrazaghnejad A, Banaie M, Safdari M. Ultrasonography in emergency department; a diagnostic tool for better examination and decision-making. Adv J Emerg Med. 2018;2(1):e7.
25. Asar S, Acibe Ö, Sabaz MS, Tontu F, Canan E, Cukurova Z, et al. Comparison of respiratory and hemodynamic parameters of COVID-19 and non-COVID-19 ARDS patients. Indian J Crit Care Med. 2021;25(6):704–8.
Files
IssueVol 6 No 2 (2022): Spring (April) QRcode
SectionOriginal article
DOI 10.18502/fem.v6i2.8711
Keywords
Artificial Respiration Cardiac Output COVID-19 Intensive Care Units Point of Care Ultrasonography

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Hedayati Emami K, Najafi A, Mojtahedzadeh M, Shariat Moharari R, Ahmadi A, Sharifinia H, Vahidi E, Zarei T, Hedayati Emami S. Ultrasonic cardiac output monitoring in intubated patients with and without COVID-19 in the ICU: a prospective cohort study. Front Emerg Med. 2021;6(2):e16.

Downloads

Download data is not yet available.

Most read articles by the same author(s)